Vener 7 Voltage Regulators

Servo-controlled across the full range, with Nairobi support. Browse by phase, cooling method or size, or use the sizing tool to match your load.

How to choose

Every Vener 7 unit is servo-controlled. Two questions narrow it down: how your supply is wired, and how the unit sheds heat.

1. Single-phase or three-phase?

Homes, shops and most loads under 30 kVA run on a single-phase 230 V supply. Factories, hospitals and anything above 30 kVA are almost always three-phase 400 V. Not sure? It is on your Kenya Power meter, or we can check on a call.

2. Air-cooled or oil-cooled?

Air-cooled is the default indoors up to 600 kVA, no fluids, easy to service. Oil-cooled suits larger or continuous-duty sites that run hot, with outdoor-cabinet options. Above 600 kVA, oil-cooled is the usual choice.

The full range

Single-Phase AVRs

For homes, small shops, workshops and single-phase machinery. Servo-controlled regulation with ±1% output tolerance. Natural air-cooled, indoor installation.

  • Capacity 3-30 kVA
  • Input range 180-270 V
  • Output 230 V ± 1%
  • Response time under 10 ms
  • Air cooled, silent operation
Learn More

Three-Phase AVRs

For factories, commercial buildings, hospitals and most industrial loads. Individually servo-controlled per phase, handles phase imbalance common on Kenyan supply.

  • Capacity 10-3000 kVA
  • Input bands 320-460 V or 340-460 V
  • Output 400 V ± 1% per phase
  • Handles phase imbalance independently
  • Air-cooled and oil-cooled variants
Learn More

Air-Cooled Range

The default choice for indoor installations up to 600 kVA. Natural air cooling, no fluid handling, straightforward maintenance. IP-30 enclosure.

  • Natural air cooling, no fluids
  • IP-30 indoor enclosure
  • Ambient range -20 °C to 50 °C
  • Single-phase: 3-30 kVA
  • Three-phase: 10-600 kVA
Learn More

Oil-Cooled Range

For larger three-phase installations where efficiency and heat management matter. Transformer-grade mineral oil cooling. Suited for heavy industrial loads and outdoor cabinets.

  • Transformer-grade oil cooling
  • Typical range 10-3000 kVA
  • Higher efficiency under continuous load
  • Outdoor-cabinet variants available
  • Suitable for heavy industrial sites
Learn More

Range at a glance

RangePhaseCoolingCapacityBest for
Single-PhaseSingleAir3–30 kVAHomes, shops, clinics
Three-PhaseThreeAir / Oil10–3000 kVAFactories, hospitals, data centers
Air-CooledSingle / ThreeAir3–600 kVAIndoor rooms, no fluid handling
Oil-CooledThreeOil10–3000 kVAHeavy / continuous-duty sites

All ranges share ±1% output regulation and servo control. Exact sizes and input bands are confirmed at quotation.